PFS TMSA 3A Series Sanitary Turbine Flow Meter

The PFS TMSA 3A Series Sanitary Turbine Flow Meter provides accurate liquid measurement for sanitary process applications. This sanitary turbine flow meter supports flow rates from 1.25 to 650 GPM, depending on meter size. It also offers 3A sanitary compliance, sanitary connections, and a minimum 32 μin Ra surface finish for hygienic service.

The TMSA 3A Series uses a 316 stainless steel meter body, a 17-4 PH stainless steel rotor, and durable bearing options. As a result, it suits demanding liquid measurement applications where cleanliness, accuracy, and repeatability matter.

Westech Industrial offers the PFS TMSA 3A Series Sanitary Turbine Flow Meter Canada wide. Our team can support product selection, service requirements, and integration into broader process systems. In addition, Westech provides custom fabrication capabilities for panels, analyzer shelters, sample systems, and integrated solutions that support complete project requirements.

Quantity

PRODUCT FEATURES

REQUEST FOR INFORMATION

Description

Sanitary Design for Liquid Measurement

The PFS TMSA 3A Series gives process teams a sanitary turbine flow meter for clean liquid measurement. It uses sanitary connections to support hygienic installation requirements. In addition, the meter meets 3A Sanitary Standards 28-04 when configured for 3A compliance. This helps facilities maintain flow measurement performance while supporting sanitary process expectations.

The meter also provides a minimum 32 μin Ra surface finish. Therefore, it suits applications where surface quality plays an important role. Teams can use this meter in processes that require careful liquid handling and repeatable flow measurement.

Wide Flow Range Across Multiple Meter Sizes

This sanitary turbine flow meter covers a broad flow range from 1.25 to 650 GPM. It also comes in sizes from 1/2 inch to 3 inches. As a result, users can match the meter size to the flow rate of their process. Smaller line sizes support lower flow requirements, while larger sizes handle higher flow rates.

This flexibility helps plants standardize on one product family across multiple flow points. It also simplifies selection when a facility needs similar sanitary turbine flow meter technology for different production areas.

Accurate and Repeatable Performance

The TMSA 3A Series delivers ±0.5% linearity over the standard flow range. It also provides ±0.1% repeatability over the standard flow range. Therefore, it helps users maintain consistent measurement results during sanitary liquid processes.

Repeatable performance matters in process control, batching, and liquid transfer applications. It also supports facilities that need dependable flow data for operational decisions.

Durable Stainless Steel Construction

The meter body uses 316 stainless steel for compatibility with sanitary process environments. The rotor uses 17-4 PH stainless steel for strength and reliable performance. In addition, available bearing materials include hard carbon composite and Rulon 123.

These material options help users configure the meter for their application. They also support long-term operation in demanding liquid measurement service.

Cleaning Method Compatibility

The PFS TMSA 3A Series supports common sanitary cleaning methods. These include CIP, SIP, COP, and SOP cleaning processes. Therefore, facilities can align the sanitary turbine flow meter with established cleaning workflows.

This compatibility helps reduce disruption during cleaning routines. It also supports hygienic process requirements in facilities that rely on regular cleaning cycles.

Pickup Coil and Configuration Options

The TMSA 3A Series offers several pickup coil options. Available configurations include a standard single magnetic coil and two magnetic pickup coils. It also supports single or dual magnetic coils with integrated pulse amplifiers.

Optional end fitting sizes also help match the meter to existing process requirements. This allows teams to select a sanitary turbine flow meter that fits the application more closely.

Applications

The PFS TMSA 3A Series Sanitary Turbine Flow Meter supports sanitary liquid measurement in processing environments. It suits applications that need accurate flow measurement, sanitary connections, and compatibility with routine cleaning methods.

  • Sanitary liquid flow measurement
  • Hygienic process lines
  • Food and beverage liquid measurement
  • Clean liquid batching
  • Liquid transfer applications
  • Process flow monitoring
  • CIP, SIP, COP, and SOP cleaning environments
  • Applications requiring 3A sanitary compliance

Documents

PFS_TMSA 3A Series Sanitary Turbine Flow Meter_Data Sheet_July2026_Westech.pdf

Manufacturer info

Primary Flow Signal designs and manufactures flow measurement solutions for liquid, gas, and steam applications. Its product offering includes Venturi flow meters, wedge-type meters, orifice flow elements, flow nozzles, and custom-engineered differential pressure measurement products for industries such as water and wastewater, oil and gas, power generation, industrial processing, automotive, and cryogenic service.

SPECS

Product:
PFS TMSA 3A Series Sanitary Turbine Flow Meter.
Meter Type:
Sanitary turbine flow meter for liquid measurement.
Available Region:
Canada wide.
Flow Meter Sizes:
1/2”, 5/8”, 3/4”, 1”, 1-1/4”, 1-1/2”, 2”, 3”.
Flow Range:
1.25 to 650 GPM.
1/2” Flow Range:
1.25 to 10 GPM.
5/8” Flow Range:
1.75 to 16 GPM.
3/4” Flow Range:
2.5 to 30 GPM.
1” Flow Range:
4 to 60 GPM.
1-1/4” Flow Range:
6 to 93 GPM.
1-1/2” Flow Range:
8 to 130 GPM.
2” Flow Range:
15 to 225 GPM.
3” Flow Range:
40 to 650 GPM.
Linearity:
±0.5% over standard flow range.
Repeatability:
±0.1% over standard flow range.
Operating Temperature:
-100°F to 450°F; consult factory for other options.
Cleaning Methods:
CIP, SIP, COP, SOP.
Surface Finish:
Minimum 32 μin Ra.
Meter Body Material:
316 stainless steel.
Rotor Material:
17-4 PH stainless steel.
Bearing Materials:
Hard carbon composite, Rulon 123.
Connections:
Sanitary.
Certifications:
3A Sanitary Standards 28-04, CRN Certified, NIST.
Style Code:
TMSA, Sanitary Style Turbine Meter.
Rebuild Kit Code:
TKSA, Sanitary Style Turbine Meter Rebuild Kit.
Pickup Coil Options:
Standard single magnetic coil, two magnetic pickup coils, single magnetic coil with integrated pulse amplifier, two magnetic coils with integrated pulse amplifiers.

PRODUCT FAQ's

What is the PFS TMSA 3A Series Sanitary Turbine Flow Meter used for?
The PFS TMSA 3A Series measures liquid flow in sanitary process applications. It supports clean liquid measurement, hygienic connections, and repeatable flow performance.
What flow range does this sanitary turbine flow meter support?
The TMSA 3A Series supports flow rates from 1.25 to 650 GPM. The exact range depends on the selected meter size.
What sizes are available?
Available flow meter sizes include 1/2”, 5/8”, 3/4”, 1”, 1-1/4”, 1-1/2”, 2”, and 3”.
What cleaning methods does the TMSA 3A Series support?
The meter supports CIP, SIP, COP, and SOP cleaning methods. This helps facilities align the meter with sanitary cleaning procedures.
Does Westech Industrial offer support for this product?
Yes. Westech Industrial can support product selection, service needs, and project requirements Canada wide. Our team can also help customers integrate the sanitary turbine flow meter into larger process solutions.
Can Westech Industrial help with custom fabrication?
Yes. Westech Industrial provides custom fabrication capabilities for integrated process solutions. This can include panels, sample systems, analyzer shelters, and other project support.