Spectrex™ FS1200 Flame Simulator

The Spectrex FS1200 Flame Simulator is a portable, rechargeable test device designed for maintenance and end-to-end testing of Spectrex ultraviolet and ultraviolet/infrared flame detectors. It allows operators to safely activate compatible flame detectors without using an open flame, helping verify detector response, alarm activation, wiring integrity, output functionality, and lens cleanliness as part of a routine fire protection system maintenance program.

Designed for handheld use by a single operator, the FS-1200 supports remote flame detector testing from practical floor or deck-level positions, helping reduce the need for scaffolding or ladders when detectors are installed in hard-to-reach areas. Its rechargeable lithium-ion battery supports at least 100 tests per charge, while laser diode aiming helps simplify detector alignment during testing.

The FS1200 Flame Simulator is available in AB, BC, and SK through Westech Industrial. Westech can also support broader fire and gas detection requirements, including detector service, troubleshooting support, and custom-fabricated fire and gas system assemblies for industrial applications.

Quantity

PRODUCT FEATURES

REQUEST FOR INFORMATION

Description

Designed for UV and UV/IR Flame Detector Testing

The Spectrex FS1200 Flame Simulator supports maintenance testing for compatible Spectrex ultraviolet and ultraviolet/infrared flame detectors. It helps operators verify detector performance during routine inspections and fire protection system checks. Additionally, it gives maintenance teams a practical tool for scheduled testing programs.

Safe Flame Simulation Without an Open Flame

The simulator produces electromagnetic radiation in a unique sequential pattern recognized by compatible Spectrex flame detectors. As a result, operators can activate the detector without using an open flame. This helps reduce testing risk while still supporting realistic flame detector verification.

Supports End-to-End Loop Testing

The FS1200 helps test more than the detector’s basic response. It can support verification of sensors, internal electronics, and alarm activation software. In addition, it helps confirm wiring integrity, relay activation, output functionality, and viewing window cleanliness. Therefore, teams can gain better confidence in the complete fire protection alarm loop.

Remote Testing from Practical Access Points

The FS1200 allows operators to test compatible detectors from floor or deck level. This can help reduce the need for ladders, scaffolding, or other access equipment. Consequently, facilities can lower maintenance time and improve testing efficiency in hard-to-reach areas.

Rechargeable Battery for Multiple Tests

A fully charged battery supports at least 100 tests before recharging is required. This makes the simulator practical for maintenance routes with multiple detectors. Moreover, the rechargeable design supports repeated use during planned inspection programs.

Portable Handheld Operation

The compact handheld design allows one operator to carry and use the simulator in the field. Its portable format helps maintenance teams move efficiently between detector locations. Therefore, the Spectrex FS1200 Flame Simulator is well suited for busy industrial sites.

Laser Diode Aiming

Built-in laser diode aiming helps the operator direct the simulator toward the detector. This feature supports more accurate positioning during testing. In turn, it can help simplify flame detector activation and reduce repeated setup attempts.

Hazardous Area Approved

The FS-1200 is approved for use in Zones 1 and 2 hazardous areas. It is also approved for Zones 21 and 22 dust hazardous areas. As a result, it can support testing programs in many industrial environments.

Durable Industrial Construction

The simulator features a heavy-duty copper-free aluminum enclosure with black zinc coating. It also includes IP65 water and dust-tight protection. These construction features help support reliable field use in demanding industrial conditions.

Applications

The Spectrex FS1200 Flame Simulator is used where flame detectors need to be tested safely, efficiently, and as part of a documented fire protection maintenance program. It is especially useful for industrial facilities where detectors are installed in elevated, hard-to-access, or hazardous locations.

Common applications include:

  • Routine flame detector maintenance and verification
  • End-to-end fire protection alarm loop testing
  • Testing compatible UV and UV/IR flame detectors
  • Hazardous area detector testing in Zones 1 and 2
  • Dust hazardous area detector testing in Zones 21 and 22
  • Oil and gas facilities
  • Chemical and petrochemical facilities
  • High-value or high-risk industrial assets
  • Locations where scaffolding or ladder access is difficult or costly

Documents

Spectrex_FS1200_Spec sheet_May2026_Westech.pdf

 

Manufacturer info

Spectrex has been a provider of optical flame and combustible gas detection solutions for the onshore, offshore, oil and gas, chemical and petrochemical industries for more than 30 years. The Spectrex fire and gas detection products are designed to the foremost safety requirements for high-risk industries and commercial applications. They can operate in the harshest environmental conditions as self-contained, stand-alone devices designed for a direct connection to control and alarm systems or automatic fire extinguishing systems.

https://www.spectrex.net/

SPECS

Product:
Spectrex SharpEye FS-1200 Flame Simulator.
Simulator Type:
Ultraviolet and ultraviolet infrared flame simulator.
Primary Use:
Maintenance and testing of compatible Spectrex flame detectors.
Compatible Detector Types:
40/40L4, L4B Legacy; 40/40U, UB, L, LB; 20/20ML Legacy; 40/40UFL Legacy; 40/40D-L4B; 40/40D, C-LB.
Testing Distance: 40/40L4, L4B Legacy:
93 ft. / 28 m detector sensitivity setting; 8 ft. / 2.5 m testing distance.
Testing Distance: 40/40U, UB, L, LB:
50 ft. / 15 m detector sensitivity setting; 20 ft. / 6 m testing distance.
Testing Distance: 20/20ML Legacy:
50 ft. / 15 m detector sensitivity setting; 20 ft. / 6 m testing distance.
Testing Distance: 40/40UFL Legacy:
60 ft. / 20 m detector sensitivity setting; 23 ft. / 7 m testing distance.
Testing Distance: 40/40D-L4B:
93 ft. / 28 m detector sensitivity setting; 6 ft. / 2 m testing distance.
Testing Distance: 40/40D, C-LB:
10 ft. / 3 m detector sensitivity setting; 3 ft. / 1 m testing distance.
Testing Distance: 40/40D, C-LB:
50 ft. / 15 m detector sensitivity setting; 11 ft. / 7 m testing distance.
Testing Distance: 40/40D-LB Only:
93 ft. / 28 m detector sensitivity setting; 46 ft. / 14 m testing distance.
Battery Type:
Rechargeable 4-cell lithium-ion battery.
Battery Power:
14.8 V (4 x 3.7 V), maximum current 0.2 A.
Charging:
16.8 V (4 x 4.2 V), maximum current 2 A.
Battery Capacity:
2.6 Ah.
Charging Time:
Two hours at 2 A.
Tests Per Charge:
At least 100 tests before recharging.
Temperature Range:
–4 °F to +122 °F (–20 °C to +50 °C).
Vibration Protection:
1 g (10 to 50 Hz).
Dimensions:
9 in. x 7.3 in. x 5.35 in. (230 mm x 185 mm x 136 mm).
Weight:
5.5 lb. (2.5 kg).
Enclosure:
Heavy-duty copper-free aluminum with black zinc coating.
Ingress Protection:
IP65 water and dust-tight.
Explosion-Proof Marking:
Ex II 2 G D; Ex db ib IIB + H₂ T₄ Gb; Ex ib tb IIIC T135 °C Db.
Hazardous Area Use:
Zones 1 and 2, Zones 21 and 22.
Standard Kit Includes:
Protective suitcase, battery nut removal tool, 1.5 mm Allen hex key, and battery charger.
Accessories:
SPX spare battery kit and 16.8 V lithium-ion charger.

PRODUCT FAQ's

What is the Spectrex FS1200 Flame Simulator used for?
The Spectrex FS1200 Flame Simulator is used to test compatible Spectrex UV and UV/IR flame detectors as part of routine maintenance and fire protection system verification. It helps confirm that the detector and connected alarm loop respond properly without requiring an open flame.
Which flame detectors is the FS-1200 designed to test?
The FS-1200 is designed for Spectrex ultraviolet and ultraviolet/infrared flame detector models, including compatible 40/40 and legacy 20/20 detector configurations listed for the FS-1200.
Does the FS1200 Flame Simulator use a real flame?
No. The FS1200 simulates the radiation pattern recognized by compatible Spectrex flame detectors, allowing the detector to be activated safely without exposing the site to an open flame.
Can the FS-1200 be used in hazardous areas?
Yes. The FS-1200 is approved for use in Zones 1 and 2 and Zones 21 and 22 hazardous areas, making it suitable for many industrial fire and gas detection maintenance programs.
How many tests can the FS-1200 perform on one charge?
A fully charged FS-1200 can operate for at least 100 tests before the battery needs to be recharged.
Why use a flame simulator instead of another test method?
A flame simulator provides a safer and more practical method for testing flame detector response, especially when detectors are mounted in hazardous or hard-to-reach areas. It can help verify detector response, outputs, relay activation, wiring integrity, and related alarm functions without the risks of live flame testing.
Can Westech Industrial support flame detector maintenance and testing?
Yes. Westech Industrial can support customers with flame and gas detection service needs, including troubleshooting, detector support, maintenance planning, and guidance on suitable testing equipment for industrial applications.
Can Westech help with custom fire and gas detection systems?
Yes. Westech Industrial provides custom fabrication capabilities for industrial safety systems, including fire and gas detection panels, integrated assemblies, and application-specific solutions designed to support site requirements.