The Ashcroft 80 Wafer Isolation Ring provides reliable pressure instrument protection in applications that require continuous pressure measurement. Its wafer-style design mounts inline with process piping and helps reduce process buildup around the measurement point. As a result, operators can maintain more accurate pressure readings while reducing maintenance concerns caused by clogging or material accumulation.

The Ashcroft 80 wafer isolation ring suits demanding water, wastewater, and mining applications. It supports nominal pipe sizes from 2″ to 20″ and offers several material combinations for wetted and non-wetted components. These options help match the isolation ring to the process media, piping requirements, and instrumentation needs.

Westech Industrial supplies the Ashcroft 80 isolation ring in Alberta and Saskatchewan. Our team can help with product selection, sizing, instrument compatibility, and service support. Westech also provides custom fabrication capabilities for related instrumentation assemblies, panels, and process measurement packages.

Quantity

PRODUCT FEATURES

REQUEST FOR INFORMATION

Description

Inline Protection for Pressure Instruments

The Ashcroft 80 Wafer Isolation Ring helps protect pressure instruments from process media. Instead of exposing the instrument directly to the process, the ring uses a flexible liner and fill fluid to transfer pressure. This design helps keep solids, slurry, and other challenging media away from the pressure instrument. Therefore, the gauge, switch, or transmitter can perform with greater reliability in difficult applications.

Non-Clogging, Low-Maintenance Design

Process buildup can cause inaccurate pressure readings and extra maintenance. The Ashcroft 80 Wafer Isolation Ring addresses this problem with a ring-style design that reduces accumulation at the sensing point. This makes it a strong choice for continuous pressure measurement in water, wastewater, and mining applications. In addition, the low-maintenance design helps reduce downtime and supports dependable operation in process piping systems.

Size and Material Flexibility

The Ashcroft 80 Wafer Isolation Ring supports nominal pipe sizes from 2″ to 20″. This range gives facilities flexibility when matching the ring to existing process piping. It also offers several end plate and liner material options. Wetted end plate materials include carbon steel, 316L stainless steel, PVDF, acetal, and CPVC. Flexible liner options include Buna-N, PTFE, EPDM, natural rubber, and Viton™. These options allow users to select materials based on media compatibility and temperature requirements.

Instrument Connection and Removal Options

The Ashcroft 80 Wafer Isolation ring supports ¼” and ½” NPT instrument connections. It also offers several instrument mounting and removal options, including direct mount, needle valve, Safe Quick Release, and needle valve with Safe Quick Release. With the SQR™ option, operators gain 360° instrument rotation, which helps with readability and positioning. This can make installation and maintenance easier in tight or awkward locations.

Retrofit and Assembly Options

The Ashcroft 80 Wafer Isolation Ring can include optional retrofit end plates for drop-in replacement of competitive units. It also offers multiple instrument assembly options, including gauge and transducer combinations or gauge and switch combinations. For vertical pipe installations, an elbow option can also support proper orientation. These options give users more flexibility when upgrading existing pressure measurement points.

NSF-61 Compliant Configuration

For applications that require NSF-61 compliance, the Ashcroft 80 Wafer Isolation Ring offers a compliant configuration with 316L stainless steel and EPDM. This option supports use in qualifying water-related applications where material approvals matter.

Applications

The Ashcroft 80 Wafer Isolation Ring supports continuous pressure measurement where process buildup, clogging, or media exposure can affect instrument performance. It works well in applications that need reliable readings and instrument protection.

  • Water treatment systems
  • Wastewater processing
  • Mining applications
  • Slurry or solids-bearing process lines
  • Pressure gauge protection
  • Pressure switch protection
  • Pressure transmitter protection
  • Process piping with challenging media

Documents

Ashcroft_80-wafer-isolation-ring-datasheet-June2026_Westech.pdf

Manufacturer info

Ashcroft® transducers/transmitters, pressure and temperature switches, thermometers, test equipment, and extensive variety of pressure gauges are manufactured for industrial and commercial ventures that require sanitary pressure instruments such as pharmaceutical, biotech and food processing applications.

http://ashcroft.com/

SPECS

Product:
Ashcroft 80 Wafer Isolation Ring.
Seal Type:
Wafer style isolation ring.
Nominal Pipe Sizes:
2" to 20".
Process Connection Ordering Codes:
02, 03, 04, 05, 06, 08, 10, 12, 14, 16, 18, 20.
Instrument Connection Sizes:
¼" NPT Female; or ½" NPT Female (ring body tapped with ¼" NPT connection, utilizes ¼"-½" NPT adapter).
Pressure Rating (MAWP):
Per customer flanges: ASME B16.5 150 or 300 class.
Instrument Options:
Direct mount, needle valve, Safe Quick Release, needle valve and SQR™.
Added Tolerance:
±0.5% typical.
Approvals:
CRN; NSF-61 with 316L stainless steel and EPDM only.
Wetted End Plate Materials:
Carbon steel, 316L stainless steel, PVDF, acetal, CPVC.
Flexible Liner Materials:
Buna-N, PTFE, EPDM, natural rubber, Viton™.
Non-Wetted Body Materials:
Carbon steel, 316L stainless steel.
Non-Wetted Instrument Fittings:
316L stainless steel adapters, 316L stainless steel needle valve, zinc-plated carbon steel SQR™.
Fill Fluids:
Glycerin, silicone 10cSt, silicone 50cSt, Halocarbon®, 50/50 ethylene glycol/water.
Glycerin Fill Temperature Range:
0°F to 400°F / -18°C to 204°C.
Silicone 10cSt Fill Temperature Range:
-40°F to 500°F / -40°C to 260°C.
Silicone 50cSt Fill Temperature Range:
-40°F to 500°F / -40°C to 260°C.
Halocarbon® Fill Temperature Range:
-80°F to 390°F / -60°C to 200°C.
50/50 Ethylene Glycol/Water Fill Temperature Range:
-25°F to 190°F / -32°C to 88°C.
Buna-N Liner Temperature Range:
-30°F to 225°F / -34°C to 107°C.
PTFE Liner Temperature Range:
-15°F to 350°F / -25°C to 177°C.
Viton™ Liner Temperature Range:
-15°F to 350°F / -25°C to 177°C.
Natural Rubber Liner Temperature Range:
-30°F to 225°F / -34°C to 107°C.
EPDM Liner Temperature Range:
-40°F to 300°F / -40°C to 149°C.
Optional Features:
Retrofit end plates; stainless steel tag wired to ring; elbow for vertical pipe installation.
Availability:
Alberta and Saskatchewan.

PRODUCT FAQ's

What does the Ashcroft 80 Wafer Isolation Ring do?
The Ashcroft 80 Wafer Isolation Ring protects pressure instruments from direct process media exposure. It helps maintain accurate pressure readings and reduces clogging concerns in continuous pressure measurement applications.
Where does the Ashcroft 80 Wafer Isolation Ring mount?
The Ashcroft 80 Wafer Isolation Ring mounts inline with process piping. Its wafer-style design fits between customer flanges.
What industries commonly use the Ashcroft 80 Wafer Isolation Ring?
Water, wastewater, and mining applications commonly use the Ashcroft 80 isolation ring. It also suits other process applications where solids, slurry, or buildup can affect pressure measurement.
What sizes are available?
The Ashcroft 80 Wafer Isolation Ring supports nominal pipe sizes from 2" to 20". Larger sizes may require factory consultation.
What instrument options are available?
Available instrument options include direct mount, needle valve, Safe Quick Release, and needle valve with SQR™. The SQR™ option allows 360° instrument rotation.
Can Westech help with selection and installation support?
Yes. Westech Industrial can help customers in Alberta and Saskatchewan select the proper Ashcroft 80 isolation ring configuration. Our team can also support related service needs, instrumentation, and custom-fabricated measurement assemblies.
Does Westech offer custom fabrication for related systems?
Yes. Westech provides custom fabrication for related instrumentation panels, measurement packages, and process solutions. This helps customers integrate the Ashcroft 80 Wafer Isolation Ring into broader pressure measurement applications.
Is the Ashcroft 80 Wafer Isolation Ring NSF-61 compliant?
The Ashcroft 80 Wafer Isolation Ring offers NSF-61 compliance with the 316L stainless steel and EPDM configuration only.